npsm logo

Table. 2.

Same as Table 1, but potential parameters that best fit the measured data when using the asymptotic velocity.
χ2/N-values were obtained under the assumption that all experimental data have a 10% error.


Target V0 rv av W0 rw aw χ2/N σR
(MeV) (fm) (fm) (MeV) (fm) (fm) (mb)
32S 75.4 0.836 0.909 34.2 1.003 0.622 2.17 1067
58Ni 85.3 0.883 0.883 40.1 1.014 0.700 2.11 1510
New Phys.: Sae Mulli 2024;74:1251~1257 https://doi.org/10.3938/NPSM.74.1251